Swch-1010, Swch-1011, Swch-1012 – Dell POWEREDGE M1000E User Manual
Page 868

846
Fabric OS Message Reference
53-1002749-01
SWCH-1010
5
SWCH-1010
Message
Trunk Area (TA) enabled on slot
enabled ports will be persistently disabled.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the blade is enabled with the port configuration that had Trunk Area enabled previously.
Recommended
Action
Disable Trunk Area on ports that had Trunk Area enabled previously. Refer to the Fabric OS
Administrator's Guide for more information.
SWCH-1011
Message
HA out of sync: Stby CP (ver=
functionality. (active ver=
Area ports exist; Otherwise '0'>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the standby control processor (CP) does not support Trunk Area functionality, but the
switch has some ports with Trunk Area enabled.
Recommended
Action
Load a firmware version on standby CP that supports Trunk Area functionality by using the
firmwareDownload command.
SWCH-1012
Message
Trunk Area (
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates that a Trunk Area has been enabled for one or more ports and the configuration file has been
updated.
Recommended
Action
No action is required.