Fabric OS Message Reference
475
53-1002749-01
FW-1206
5
FW-1206
Message
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the trunk utilization is above its threshold level.
Recommended
Action
Increase the bandwidth by adding more links to the trunk.
FW-1207
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the trunk utilization is between the low and high thresholds.
Recommended
Action
No action is required.
FW-1216
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of Arbitrated Loop Physical Address (ALPA) cyclic redundancy check (CRC)
errors has changed. This indicates that errors have been detected in the FC frame. Invalid CRC
messages occur when the number of CRC errors in Fibre Channel frames for specific source ID (S_ID)
and destination ID (D_ID) pairs change. These messages might also be caused by dirty equipment,
temperature fluctuations, and aging equipment. You should set your high boundaries to five- or six-digit
figures, because only large numbers of messages indicate a problem in this area.
Recommended
Action
Verify that your optical components are clean and function properly. Replace deteriorating cables or
small form-factor pluggables (SFPs). Check for damage from heat or age.