Ps messages, Ps-1000, Ps-1001 – Dell POWEREDGE M1000E User Manual
Page 682: Ps-1002

660
Fabric OS Message Reference
53-1002749-01
PS-1000
5
PS Messages
PS-1000
Message
Failed to initialize Advanced Performance Monitoring.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that an unexpected software error has occurred in Advanced Performance Monitoring. The
Performance Monitor has failed to initialize.
Recommended
Action
The control processor (CP) will reboot or failover automatically. If it does not, reboot or power cycle the
switch to reinitiate the firmware.
PS-1001
Message
Advanced Performance Monitoring configuration updated due to change in PID format.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the port ID (PID) format was changed.
Recommended
Action
No action is required. Refer to the Fabric OS Administrator's Guide for more information about the PID
format.
PS-1002
Message
Failed to initialize the tracing system for Advanced Performance Monitoring.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that an unexpected software error has occurred in Advanced Performance Monitoring. The
Performance Monitor tracing system has failed to initialize.
Recommended
Action
Tracing will not be available for Advanced Performance Monitoring, but other functions will function
normally. To activate tracing, reboot or failover the control processor (CP).