Fabric OS Message Reference

507

53-1002749-01

FW-1361

5

Recommended

Action

Responses to security-class messages depend on user policies. Consult your security administrator for
response strategies and policies.

FW-1361

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of switch link authentication protocol (SLAP) faulty packets has fallen below
the low boundary. This counter keeps track of the number of unexpected SLAP packets and SLAP
packets with faulty transmission IDs.

Recommended

Action

No action is required.

FW-1362

Message

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the number of Switch Link Authentication Protocol (SLAP) faulty packets has risen above
the high boundary. This counter keeps track of the number of unexpected SLAP packets and SLAP
packets with faulty transmission IDs.

Recommended

Action

Responses to security-class messages depend on user policies. Consult your security administrator for
response strategies and policies.

FW-1363

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of Switch Link Authentication Protocol (SLAP) faulty packets has changed from
a value outside of the acceptable range to a value within the acceptable range. This counter keeps track
of the number of unexpected SLAP packets and SLAP packets with faulty transmission IDs.

Recommended

Action

No action is required.