beautypg.com

Conf-1021, Conf-1022, Conf-1023 – Dell POWEREDGE M1000E User Manual

Page 262

background image

240

Fabric OS Message Reference

53-1002749-01

CONF-1021

5

CONF-1021

Message

configUpload not permitted .

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a configUpload operation is not permitted. There are many possible causes.

Recommended

Action

Execute the errShow command to view the error log. Correct the error and execute the configUpload
command again.

CONF-1022

Message

Downloading configuration without disabling the switch was unsuccessful.

Message Type

AUDIT

Class

CFG

Severity

WARNING

Probable Cause

Indicates an attempt to download the configuration without disabling the switch was unsuccessful
because there are one or more parameters that require the switch to be disabled.

Recommended

Action

Disable the switch using the switchDisable command and download the configuration.

CONF-1023

Message

configDownload failed .

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a configDownload operation has failed.

Recommended

Action

Execute the errShow command to view the error log. Correct the error and execute the
configDownload command again.