CONF-1021
5
CONF-1021
Message
configUpload not permitted
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a configUpload operation is not permitted. There are many possible causes.
Recommended
Action
Execute the errShow command to view the error log. Correct the error and execute the configUpload
command again.
CONF-1022
Message
Downloading configuration without disabling the switch was unsuccessful.
Message Type
AUDIT
Class
CFG
Severity
WARNING
Probable Cause
Indicates an attempt to download the configuration without disabling the switch was unsuccessful
because there are one or more parameters that require the switch to be disabled.
Recommended
Action
Disable the switch using the switchDisable command and download the configuration.
CONF-1023
Message
configDownload failed
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a configDownload operation has failed.
Recommended
Action
Execute the errShow command to view the error log. Correct the error and execute the
configDownload command again.