Fw-1036, Fw-1037, Fw-1038 – Dell POWEREDGE M1000E User Manual
Page 465
Fabric OS Message Reference
443
53-1002749-01
FW-1036
5
FW-1036
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the temperature of the small form-factor pluggable (SFP) has changed from a value
outside of the acceptable range to a value within the acceptable range. Frequent fluctuations in
temperature may indicate a deteriorating SFP.
Recommended
Action
No action is required.
FW-1037
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The
receive performance area measures the amount of incoming laser to help you determine whether the
SFP is in good working condition. If the counter often exceeds the threshold, the SFP is deteriorating.
Recommended
Action
Incoming laser fluctuations usually indicate a deteriorating SFP. If the message persists, replace the SFP.
FW-1038
Message
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the receive power value of the small form-factor pluggable (SFP) has fallen below the low
boundary. The receive performance area measures the amount of incoming laser to help you determine
whether the SFP is in good working condition. If the counter often exceeds the threshold, the SFP is
deteriorating.
Recommended
Action
Verify that your optical components are clean and function properly. Replace deteriorating cables or
SFPs. Check for damage from heat or age.