53-1002749-01
FSPF-1005
5
FSPF-1005
Message
Wrong Section Id
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that an incorrect section ID was reported from the specified input port. The section ID is part of
the fabric shortest path first (FSPF) protocol and is used to identify a set of switches that share an
identical topology database.
Recommended
Action
This switch does not support a non-zero section ID. Any connected switch from another manufacturer
with a section ID other than 0 is incompatible in a fabric of Brocade switches. Disconnect the
incompatible switch.
FSPF-1006
Message
FSPF Version
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the fabric shortest path first (FSPF) version is not supported on the specified input port.
Recommended
Action
Update the FSPF version by running the firmwareDownload command. All current versions of the
Fabric OS support FSPF version 2.
FSPF-1007
Message
ICL triangular topology is broken between the neighboring domains:
and
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the inter-chassis link (ICL) triangular topology is broken and becomes linear. It may cause
frame drop or performance slowdown.
Recommended
Action
Connect the two domains using ICL or regular inter-switch link (ISL) to form a triangular topology.