Chs messages, Chs-1002, Chs-1003 – Dell POWEREDGE M1000E User Manual
Page 236: Chs-1004

214
Fabric OS Message Reference
53-1002749-01
CHS-1002
5
CHS Messages
CHS-1002
Message
ki_gd_register_action failed with rc =
Message Type
LOG | FFDC
Severity
ERROR
Probable Cause
Indicates an internal error.
Recommended
Action
To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastBoot command on the switch.
CHS-1003
Message
Slot ENABLED but Not Ready during recovery, disabling slot =
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the slot state has been detected as inconsistent during failover or recovery.
Recommended
Action
For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.
For a non-bladed switch, restart or power cycle the switch.
CHS-1004
Message
Blade attach failed during recovery, disabling slot =
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified blade has failed during failover or recovery.
Recommended
Action
For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.
For a non-bladed switch, restart or power cycle the switch.