460

Fabric OS Message Reference

53-1002749-01

FW-1162

5

FW-1162

Message

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the number of link failures that the port experiences has risen above the high boundary.
Link loss errors occur when a link experiences a loss of signal and fails. Both physical and hardware
problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization.

Recommended

Action

Check both ends of your cable connection. Verify that the cable and small form-factor pluggables (SFPs)
are not faulty.

Losses of synchronization commonly cause link failures. If you receive concurrent loss of
synchronization errors, troubleshoot the loss of synchronization.

FW-1163

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of link failures that the port experiences has changed from a value outside of
the acceptable range to a value within the acceptable range. Link loss errors occur when a link
experiences a loss of signal and fails. Both physical and hardware problems can cause link loss errors.
Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of
synchronization errors and, if applicable, troubleshoot them.

Recommended

Action

Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. Respond to this
message as is appropriate to the particular policy of the end-user installation.

FW-1164

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of synchronization losses that the port experiences has changed. Loss of
synchronization errors frequently occur due to a faulty small form-factor pluggable (SFP) or cable. Signal