BM-1010
5
BM-1010
Message
Resetting port configuration and linkcost for all ports for blade in slot
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the specified blade was detected for the first time after an FC10-6 was previously configured in
the same slot. The new blade requires resetting the port configuration and linkcost.
Recommended
Action
No action is required. The blade ports are cleared automatically.
BM-1053
Message
Failed to establish connection between CP and Application Processor. Faulting
switch.
Message Type
LOG | FFDC
Severity
WARNING
Probable Cause
Indicates that the control processor (CP) could not establish a connection with the application processor
(AP) to communicate.
Recommended
Action
Execute the slotPowerOff and slotPowerOn commands or reseat the affected blade.
BM-1054
Message
AP firmware
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the policy of the specified blade is set to auto-level the blade firmware to the system
firmware. This may be due to one of the following reasons:
•
Blade firmware was detected to be different from the control processor (CP) firmware due to a
firmware upgrade.
•
The blade was recently inserted and had a different version of the firmware loaded.
Recommended
Action
No action is required. The blade will automatically download the updated firmware.