beautypg.com

Fw-1048, Fw-1049, Fw-1050 – Dell POWEREDGE M1000E User Manual

Page 469

background image

Fabric OS Message Reference

447

53-1002749-01

FW-1048

5

FW-1048

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

FW-1049

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the value of the small form-factor pluggable (SFP) voltage has changed. Frequent voltage
fluctuations indicate that the SFP is deteriorating.

Recommended

Action

Replace the SFP.

FW-1050

Message

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the value of the small form-factor pluggable (SFP) voltage has fallen below the low
boundary.

Recommended

Action

Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0
(Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates.