Fabric OS Message Reference
447
53-1002749-01
FW-1048
5
FW-1048
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
FW-1049
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has changed. Frequent voltage
fluctuations indicate that the SFP is deteriorating.
Recommended
Action
Replace the SFP.
FW-1050
Message
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has fallen below the low
boundary.
Recommended
Action
Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0
(Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates.