Spc-3011, Spc-3012, Spc-3013 – Dell POWEREDGE M1000E User Manual
Page 810

788
Fabric OS Message Reference
53-1002749-01
SPC-3011
5
SPC-3011
Message
S
storage error:
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that an attempt to store CryptoModule internal data using the Secret Encryption Key failed;
most likely, the encryption engine has been zeroized or tampered with.
Recommended
Action
Execute the cryptocfg --initEE and cryptocfg --regEE commands, and then recover or restore the
needed primary and secondary KEKs.
SPC-3012
Message
S
retrieval error:
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that an attempt to read CryptoModule internal data using the Secret Encryption Key failed;
most likely, the encryption engine has been zeroized or tampered with.
Recommended
Action
Execute the cryptocfg --initEE and cryptocfg --regEE commands, and then recover or restore the
needed primary and secondary KEKs.
SPC-3013
Message
S
failure:
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the CryptoModule internal Secret Encryption Key could not be generated.
Recommended
Action
Contact your switch service provider for assistance.