788

Fabric OS Message Reference

53-1002749-01

SPC-3011

5

SPC-3011

Message

S, : Persistent data
storage error: , KEK:
.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that an attempt to store CryptoModule internal data using the Secret Encryption Key failed;
most likely, the encryption engine has been zeroized or tampered with.

Recommended

Action

Execute the cryptocfg --initEE and cryptocfg --regEE commands, and then recover or restore the
needed primary and secondary KEKs.

SPC-3012

Message

S, : Persistent data
retrieval error: .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that an attempt to read CryptoModule internal data using the Secret Encryption Key failed;
most likely, the encryption engine has been zeroized or tampered with.

Recommended

Action

Execute the cryptocfg --initEE and cryptocfg --regEE commands, and then recover or restore the
needed primary and secondary KEKs.

SPC-3013

Message

S, : SEK generation
failure: .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the CryptoModule internal Secret Encryption Key could not be generated.

Recommended

Action

Contact your switch service provider for assistance.