Fabric OS Message Reference
465
53-1002749-01
FW-1176
5
FW-1176
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of invalid words that the port experiences has changed. Invalid words usually
indicate a hardware problem with a small form-factor pluggable (SFP) or cable.
Recommended
Action
Verify that both ends of the connections, the SFP, and the cable are not faulty.
FW-1177
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of invalid words that the port experiences has fallen below the low boundary.
Invalid words usually indicate a hardware problem with a small form-factor pluggable (SFP) or cable. A
low number of invalid words means that the switch is functioning normally.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
FW-1178
Message
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the number of invalid words that the port experiences has risen above the high boundary.
Invalid words usually indicate a hardware problem with a small form-factor pluggable (SFP) or cable.
Recommended
Action
Verify that both ends of the connections, the SFP, and the cable are not faulty.