background image

782

Fabric OS Message Reference

53-1002749-01

SPC-2013

5

SPC-2013

Message

S, : Oscillator Failure
Detected.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates hardware failure.

Recommended

Action

The shelf life of the system may be reduced. Contact the vendor for further instructions.

SPC-2014

Message

S, : Low Battery Level
Detected.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the battery is depleted.

Recommended

Action

System operation will be unaffected while the facility power is present. Schedule battery replacement
with the vendor.

SPC-2040

Message

S, : SPD Device minornum
is already open. state .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the Security Policy Database (SPD) device has already opened or is busy for sysctrld or
keyappd.

Recommended

Action

No action is required.