beautypg.com

Esw-1004, Esw-1005, Esw-1006 – Dell POWEREDGE M1000E User Manual

Page 323

background image

Fabric OS Message Reference

301

53-1002749-01

ESW-1004

5

ESW-1004

Message

Blade attach failed during recovery, disabling slot = .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified blade has failed during failover or recovery.

Recommended

Action

For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.

For a non-bladed switch, restart or power cycle the switch.

ESW-1005

Message

Diag attach failed during recovery, disabling slot = .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the diagnostic blade attach operation has failed during failover or recovery.

Recommended

Action

For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.

For a non-bladed switch, restart or power cycle the switch.

ESW-1006

Message

HA state out of sync: Standby CP (ver = ) does not support
NPIV functionality. (active ver = , NPIV devices = <'1' if
NPIV devices exist; Otherwise '0'>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the standby control processor (CP) does not support N_Port ID Virtualization (NPIV)
functionality, but the switch has some NPIV devices logged in to the fabric.

Recommended

Action

Load a firmware version on the standby CP that supports NPIV functionality using the
firmwareDownload command.