CVLC-1007
5
CVLC-1007
Message
Removal of encryption LUN is not allowed when decrypt of existing data is enabled.
Container:
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that there has been an attempt to remove the encryption LUN while decryption of existing data
is still enabled.
Recommended
Action
To preserve the user data, execute the cryptocfg --modify -LUN -cleartext command to convert to
cleartext LUN.
Use the cryptocfg --modify -LUN -cleartext command to disable decryption of existing data.
Then try to delete the LUN again.
CVLC-1008
Message
LUN discovery failure:
Initiator:
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that LUN discovery failed.
Recommended
Action
No action is required.
CVLC-1009
Message
Wrong device type: should be
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that LUN discovery failed.
Recommended
Action