beautypg.com

Cvlc-1007, Cvlc-1008, Cvlc-1009 – Dell POWEREDGE M1000E User Manual

Page 269

background image

Fabric OS Message Reference

247

53-1002749-01

CVLC-1007

5

CVLC-1007

Message

Removal of encryption LUN is not allowed when decrypt of existing data is enabled.
Container: , Initiator: , LUN ID:
.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that there has been an attempt to remove the encryption LUN while decryption of existing data
is still enabled.

Recommended

Action

To preserve the user data, execute the cryptocfg --modify -LUN -cleartext command to convert to
cleartext LUN.

Use the cryptocfg --modify -LUN -cleartext command to disable decryption of existing data.

Then try to delete the LUN again.

CVLC-1008

Message

LUN discovery failure: , Container: ,
Initiator: , LUN ID: .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that LUN discovery failed.

Recommended

Action

No action is required.

CVLC-1009

Message

Wrong device type: should be , found device type (Disk/Tape)>. Container: , Initiator:
, LUN ID: .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that LUN discovery failed.

Recommended

Action

No action is required.