beautypg.com

C3-1012, C3-1013, C3-1014 – Dell POWEREDGE M1000E User Manual

Page 219

background image

Fabric OS Message Reference

197

53-1002749-01

C3-1012

5

C3-1012

Message

S,P(): Link Timeout on internal port
ftx= tov= (>)
vc_no= crd(s)lost= complete_loss:loss>.

Message Type

LOG | FFDC

Severity

CRITICAL

Probable Cause

Indicates that one or more credits have been lost on a back-end port, and there is no traffic on that port
for two seconds.

Recommended

Action

Turn on the back-end credit recovery to reset the link and recover the lost credits. If credit recovery has
already been turned on, the link will be reset to recover the credits and no action is required.

C3-1013

Message

Multi RDY/Frame Loss detected on Slot , Port (port number>) m_rdy(0x)/m_frame(0xLost>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that wait cycles to recover the lost frame or credit are exceeded on the specified port.

Recommended

Action

Turn on the back-end credit recovery to reset the link and recover the lost credits. If credit recovery has
already been turned on, the link will be reset to recover the credits and no action is required.

C3-1014

Message

Link Reset on Port S,P() vc_no=number> crd(s)lost= trigger.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that one or more credits were lost and the link is reset.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.