Ras messages, Ras-1001, Ras-1002 – Dell POWEREDGE M1000E User Manual
Page 689: Ras-1004

Fabric OS Message Reference
667
53-1002749-01
RAS-1001
5
RAS Messages
RAS-1001
Message
First failure data capture (FFDC) event occurred.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a first failure data capture (FFDC) event occurred and the failure data has been captured.
Recommended
Action
Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.
RAS-1002
Message
First failure data capture (FFDC) maximum storage size (
reached.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the storage size for first failure data capture (FFDC) data has reached the maximum.
Recommended
Action
Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.
RAS-1004
Message
Software 'verify' error detected.
Message Type
LOG | FFDC
Severity
WARNING
Probable Cause
Indicates an internal software error.
Recommended
Action
Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.