beautypg.com

Hil-1301, Hil-1302, Hil-1303 – Dell POWEREDGE M1000E User Manual

Page 575

background image

Fabric OS Message Reference

553

53-1002749-01

HIL-1301

5

HIL-1301

Message

1 blower failed or missing. Replace failed or missing blower assembly immediately.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a fan field-replaceable unit (FRU) has failed or has been removed. This message is often
preceded by a low speed error message. This problem can cause the switch to overheat.

Recommended

Action

Replace the affected fan FRU immediately.

HIL-1302

Message

blowers failed or missing. Replace failed or missing blower assemblies
immediately.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that multiple fan field-replaceable units (FRUs) have failed or are missing on a switch. This
message is often preceded by a low fan speed message.

Recommended

Action

Replace the affected fan FRUs immediately.

HIL-1303

Message

One fan failed. Replace failed fan FRU immediately.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that a fan field-replaceable unit (FRU) has failed. This message is often preceded by a low fan
speed message.

Recommended

Action

Replace the faulty fan FRU immediately.