beautypg.com

Fw-1402, Fw-1403, Fw-1404 – Dell POWEREDGE M1000E User Manual

Page 537

background image

Fabric OS Message Reference

515

53-1002749-01

FW-1402

5

FW-1402

Message

Message Type

AUDIT | LOG

Class

FW

Severity

WARNING

Probable Cause

Indicates that the flash memory usage percentage has risen above the high boundary. Flash memory
increases and decreases slightly with normal operation of the switch.

Recommended

Action

Remove some unwanted files to create some flash space. Execute the supportSave command to
remove files from the kernel space.

FW-1403

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the CPU or memory usage is between the boundary limits.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

FW-1404

Message

Message Type

AUDIT | LOG

Class

FW

Severity

WARNING

Probable Cause

Indicates that the CPU or memory usage is above its threshold. If this RASLOG pertains to memory
usage, then the usage is above the middle memory threshold.

Recommended

Action

No action is required.