beautypg.com

Cdr-1004, Cdr-1005, Cdr-1006 – Dell POWEREDGE M1000E User Manual

Page 230

background image

208

Fabric OS Message Reference

53-1002749-01

CDR-1004

5

CDR-1004

Message

S,C: Invalid DMA ch pointer, chan:,
good_addr:0x bad_addr:0x.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.

Recommended

Action

Restart the system at the next maintenance window. If the problem persists, replace the blade.

CDR-1005

Message

S,P(): best effort QoS will be turned
off at next port state change as it is not supported under this configuration.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that quality of service (QoS) will be turned off automatically at the next port state change
because best effort QoS is no longer supported on 4 Gbps or 8 Gbps platform long distance ports.

Recommended

Action

No action is required.

CDR-1006

Message

S,P(): QoS overwrites
portcfglongdistance vc_translation_link_init. ARB will be used on the link.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that quality of service (QoS) has overwritten the fill word IDLE used on the long distance links.
Arbitrated loop (ARB) will be used on the link.

Recommended

Action

No action is required.