Fabric OS Message Reference
53-1002749-01
CDR-1004
5
CDR-1004
Message
S
good_addr:0x
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the blade.
CDR-1005
Message
S
off at next port state change as it is not supported under this configuration.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that quality of service (QoS) will be turned off automatically at the next port state change
because best effort QoS is no longer supported on 4 Gbps or 8 Gbps platform long distance ports.
Recommended
Action
No action is required.
CDR-1006
Message
S
portcfglongdistance vc_translation_link_init. ARB will be used on the link.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that quality of service (QoS) has overwritten the fill word IDLE used on the long distance links.
Arbitrated loop (ARB) will be used on the link.
Recommended
Action
No action is required.