FICN-1030
Message
HostDiskIng:FICON Purge received:Path=0x
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an active disk emulation device received a FICON Purge Path from the channel.
Recommended
Action
If there was an unexpected job failure or I/O error associated with this event, contact your vendor's
customer support for assistance.
FICN-1031
Message
HostDiskIng:FICON System Reset received on Path=0x
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates the FICON channel sent a System Reset to the disk control unit.
Recommended
Action
No action is required. The MVS system was either set to initial program load (IPL) or performing error
recovery.
FICN-1032
Message
HostDiskIng:XRC Read Channel Extender Capabilities detected on Path:
0x
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the eXtended Remote Copy (XRC) System Data mover was restarted to discover the
capabilities of the channel extension equipment.
Recommended
Action
No action is required. This is a part of the XRC initialization.