359
53-1002749-01
FCR-1054
5
FCR-1054
Message
Port
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that an internal link service (ILS) IU of invalid size was received from the switch on the other
end of the link.
Recommended
Action
Check the error message log on the other switch using the errShow command for additional messages.
Check for a faulty cable or deteriorated small form-factor pluggable (SFP). Replace the cable or the SFP
if necessary.
Run the portLogDumpPort command on both the receiving and transmitting ports.
Run the fabStatsShow command on the transmitting switch.
If the message persists, collect switch information using the supportSave command, and contact your
switch service provider.
FCR-1055
Message
Switch with domain ID
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a switch that does not support backbone-to-edge routing was detected in the backbone.
Edge-to-edge routing will work, but backbone-to-edge routing may fail.
Recommended
Action
No action is required if backbone-to-edge routing is not required. Otherwise, replace the switch with one
that supports backbone-to-edge routing.
FCR-1056
Message
Switch
edge imports.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a switch that does not support backbone-to-edge routing is running in the MetaSAN.
Recommended
Action
No action is required if backbone-to-edge routing is not needed. Otherwise, replace the switch with one