192

Fabric OS Message Reference

53-1002749-01

C2-1019

5

C2-1019

Message

S,C: HW ASIC Chip TXQ FID parity error threshold reached
type = 0x.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that an internal error is observed in the application-specific integrated circuit (ASIC) hardware
that may degrade the data traffic.

Recommended

Action

Restart the system at the next maintenance window.

C2-1025

Message

S,P(): Extra credit on
F_port:ftx= curr_cred= actual_cred=.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the device is returning the wrong number of receiver-ready (R_RDY) frames.

Recommended

Action

When this error is observed persistently, replace the device.

C2-1026

Message

S,P(): Faulting F_port due to extra
credit detected:ftx= curr_cred= actual_cred=credits>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the device is returning the wrong number of receiver-ready (R_RDY) frames.

Recommended

Action

When this error is observed persistently, replace the device.