AN-1001

5

AN Messages

AN-1001

Message

Failed to allocate memory: ().

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified function has failed to allocate memory.

Recommended

Action

Check memory usage on the switch using the memShow command. Restart or power cycle the switch.

AN-1002

Message

Failed to initialize; rc = .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the initialization of the "trafd" daemon has failed.

Recommended

Action

Download a new firmware version using the firmwareDownload command.

AN-1003

Message

Latency bottleneck on port /.
pct. of period over which the percentage of affected seconds is reported> secs. affected.
Avg. delay us. Avg.
slowdown .

Message Type

LOG | AUDIT

Class

FABRIC

Severity

WARNING

Probable Cause

For an F_Port, indicates that the attached device is slow in responding to frames going out of the
specified port. This latency may be inherent in the device or due to heavy workload on the device.

For a long-distance E_Port, may indicate too few credits for the distance. For a non-long-distance
E_Port, indicates latency produced by a device downstream of the E_Port and is an indication of
back-pressure produced by that latency.