AN-1001
5
AN Messages
AN-1001
Message
Failed to allocate memory: (
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified function has failed to allocate memory.
Recommended
Action
Check memory usage on the switch using the memShow command. Restart or power cycle the switch.
AN-1002
Message
Failed to initialize; rc =
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the initialization of the "trafd" daemon has failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command.
AN-1003
Message
Latency bottleneck on port
Avg. delay
slowdown
Message Type
LOG | AUDIT
Class
FABRIC
Severity
WARNING
Probable Cause
For an F_Port, indicates that the attached device is slow in responding to frames going out of the
specified port. This latency may be inherent in the device or due to heavy workload on the device.
For a long-distance E_Port, may indicate too few credits for the distance. For a non-long-distance
E_Port, indicates latency produced by a device downstream of the E_Port and is an indication of
back-pressure produced by that latency.