Auth-1026, Auth-1027, Auth-1028 – Dell POWEREDGE M1000E User Manual
Page 173
Fabric OS Message Reference
151
53-1002749-01
AUTH-1026
5
AUTH-1026
Message
Failed to
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the authentication failed to get device or Host Bus Adapter (HBA) information due to an
internal failure. Usually this problem is transient. If the authentication failed, retry the login.
Recommended
Action
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
AUTH-1027
Message
Failed to select
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the authentication process failed to select an authentication value (DH Group, hash value,
or protocol type) from a receiving payload for a particular authentication phase. This indicates that the
local switch does not support the specified authentication value.
Recommended
Action
Check the authentication configuration and reset the supported value if needed using the authUtil
command.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
AUTH-1028
Message
Failed to allocate for
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the authentication process failed because the system is low on memory. Usually this
problem is transient. The authentication may fail.
The Data type is the payload or structure that failed to get memory. The Operation phase specifies which
operation of a particular authentication phase failed.