Trce-1010, Trce-1011, Trce-1012 – Dell POWEREDGE M1000E User Manual
Page 883

Fabric OS Message Reference
861
53-1002749-01
TRCE-1010
5
TRCE-1010
Message
Traced fails to start.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the trace daemon (traced), which is used for transferring trace files has failed to start. The
trace capability within the switch is unaffected. The system automatically restarts the traced facility after a
brief delay.
Recommended
Action
Reboot the CP (dual-CP system) or restart the switch.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
TRCE-1011
Message
Trace dump manually transferred to target '
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the trace dump files were manually transferred to the specified slot.
Recommended
Action
No action is required.
TRCE-1012
Message
The system was unable to retrieve trace information from slot
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the system was unable to retrieve trace information from the specified slot because there is
no communication between the main system and the specified slot.
Recommended
Action
Make sure the blade is enabled and retry the command. If the blade is already enabled, execute the
supportSave command and contact your switch service provider.