Sec-1078, Sec-1079, Sec-1080 – Dell POWEREDGE M1000E User Manual
Page 728
706
Fabric OS Message Reference
53-1002749-01
SEC-1078
5
SEC-1078
Message
No new data to abort.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates there are no new changes in the defined security policy database that can be aborted.
Recommended
Action
Verify the security event was planned. Verify if there were really any changes to the defined policy
database that can be aborted.
SEC-1079
Message
The policy name
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates the policy name entered in the secPolicyCreate, secPolicyActivate, secPolicyAdd, or
secPolicyDelete command was invalid.
Recommended
Action
Run the command again using a valid policy name.
SEC-1080
Message
Operation denied. Please use secPolicyActivate or distribute commands.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Action
Run the fabricShow command to verify that the fabric is still consistent. All the switches should be in the
ready state. If a switch is in the error state, the database may not be correctly updated for that specific
switch.