beautypg.com

Ficn-1009, Ficn-1010, Ficn-1011 – Dell POWEREDGE M1000E User Manual

Page 398

background image

376

Fabric OS Message Reference

53-1002749-01

FICN-1009

5

FICN-1009

Message

DevIng:CmdReject Sense Data rcvd:Path=0xDeviceDomain> LastCmds=0xissued to the device> Sense Data:Bytes0-0xB=0xdevice>the device>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates a Unit Check status was received from a device and a sense command was issued to read the
sense data.

Recommended

Action

If there was a job failure associated with this event, contact your vendor's customer support for
assistance.

FICN-1010

Message

DevDiskEgr:Device level exception flag found for Path=0xHostPort DeviceDomain>: Oxid=0xwas reported in the Device Level Exception Frame>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates a Device Level Exception frame was received from the FICON channel.

Recommended

Action

If there was a job or I/O failure associated with this event, contact your vendor's customer support for
assistance.

FICN-1011

Message

DevDiskIng:XRC Incorrect RRS SeqNum Rcvd Path=0xDeviceDomain> Expected=0xnumber that was expected from the device> Received=0xwas actually received from the device> Oxid=0x.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the Control unit or device presented a Read Record Set Sequence number different from the
SDM's expected sequence number.

Recommended

Action

If there was an XRC volume or session suspended associated with this event, contact your vendor's
customer support for assistance.