Ips-1004, Ips-1005, Ips-1006 – Dell POWEREDGE M1000E User Manual
Page 598

576
Fabric OS Message Reference
53-1002749-01
IPS-1004
5
IPS-1004
Message
Port Config Mode Mismatch slot (
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that configured port mode is different from the intended use.
Recommended
Action
Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the port
mode to neutral before attempting to configure the port for a different mode or use.
IPS-1005
Message
Tunnel Authorization Failure for slot (
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that tunnel setup failed because of an authorization failure from the remote side. A reason for
such a failure could be a WWN mismatch.
Recommended
Action
Change the tunnel configuration on one side of the tunnel to authorize the remote side to set up the
tunnel.
IPS-1006
Message
Tunnel Configuration Mismatch for slot (
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that tunnel setup failed because of a configuration mismatch between the two ends. The
reason field indicates the cause for configuration mismatch.
Recommended
Action
Change the tunnel configuration on one side of the tunnel to match that of the other side to set up the
tunnel.