beautypg.com

Em-1011, Em-1012, Em-1013 – Dell POWEREDGE M1000E User Manual

Page 303

background image

Fabric OS Message Reference

281

53-1002749-01

EM-1011

5

EM-1011

Message

Received unexpected power down for , but cannot determine if it has power.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the environmental monitor (EM) received an unexpected power-down notification from the
specified field-replaceable unit (FRU). However, after four seconds, it cannot be determined if it has
powered down or not.

Recommended

Action

Reseat the blade. If the problem persists, replace the blade.

EM-1012

Message

failed state transition, unit faulted.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that a switch blade or non-bladed switch failed to transition from one state to another. It is
faulted. The specific failed target state is displayed in the message. There are serious internal Fabric OS
configuration or hardware problems on the switch.

Recommended

Action

Reseat the specified field-replaceable unit (FRU).

If the problem persists, restart or power cycle the switch.

Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade by using the slotPowerOff and slotPowerOn commands or have the blade's ejector
switch cycled to run POST and verify that the blade does not have any hardware problems.

If the problem still persists, replace the FRU.

EM-1013

Message

Failed to update FRU information for .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the environmental monitor (EM) was unable to update the time alive or original equipment
manufacturer (OEM) data in the memory of a field-replaceable unit (FRU).

Recommended

Action

If you executed the fruInfoSet command, execute the command again; otherwise, the update is
automatically attempted again. If it continues to fail, reseat the FRU.