Em-1011, Em-1012, Em-1013 – Dell POWEREDGE M1000E User Manual
Page 303
Fabric OS Message Reference
281
53-1002749-01
EM-1011
5
EM-1011
Message
Received unexpected power down for
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that the environmental monitor (EM) received an unexpected power-down notification from the
specified field-replaceable unit (FRU). However, after four seconds, it cannot be determined if it has
powered down or not.
Recommended
Action
Reseat the blade. If the problem persists, replace the blade.
EM-1012
Message
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that a switch blade or non-bladed switch failed to transition from one state to another. It is
faulted. The specific failed target state is displayed in the message. There are serious internal Fabric OS
configuration or hardware problems on the switch.
Recommended
Action
Reseat the specified field-replaceable unit (FRU).
If the problem persists, restart or power cycle the switch.
Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade by using the slotPowerOff and slotPowerOn commands or have the blade's ejector
switch cycled to run POST and verify that the blade does not have any hardware problems.
If the problem still persists, replace the FRU.
EM-1013
Message
Failed to update FRU information for
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the environmental monitor (EM) was unable to update the time alive or original equipment
manufacturer (OEM) data in the memory of a field-replaceable unit (FRU).
Recommended
Action
If you executed the fruInfoSet command, execute the command again; otherwise, the update is
automatically attempted again. If it continues to fail, reseat the FRU.