beautypg.com

Fw-1529, Fw-1530, Fw-1531 – Dell POWEREDGE M1000E User Manual

Page 555

background image

Fabric OS Message Reference

533

53-1002749-01

FW-1529

5

FW-1529

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of link resets that the port experiences has changed and crossed the lower
threshold boundary to a value within the acceptable range. Link resets occur due to link timeout errors
that indicate no frame activity at all. Both physical and hardware problems can cause link resets to
increase.

Recommended

Action

Respond to this message as is appropriate to the particular policy of the end-user installation.

FW-1530

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of link resets that the port experiences has changed and dropped below the
upper threshold boundary to a value within the acceptable range. Link resets occur due to link timeout
errors that indicate no frame activity. Both physical and hardware problems can cause link resets to
increase.

Recommended

Action

Respond to this message as is appropriate to the particular policy of the end-user installation.

FW-1531

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of C3 transmit timeout frames has crossed the lower threshold boundary and is
in between the low and high thresholds.

Recommended

Action

Check the target device; it could be slow.