Pdm-1010, Pdm-1011, Pdm-1012 – Dell POWEREDGE M1000E User Manual
Page 667

Fabric OS Message Reference
645
53-1002749-01
PDM-1010
5
PDM-1010
Message
File open failed:
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the Parity Data Manager (PDM) process could not open the specified file.
Recommended
Action
Execute the firmwareDownload command to reinstall the firmware.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
PDM-1011
Message
File read failed:
expected=
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the Parity Data Manager (PDM) process could not read data from the specified file.
Recommended
Action
Execute the firmwareDownload command to reinstall the firmware.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
PDM-1012
Message
File write failed:
write=
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the Parity Data Manager (PDM) process could not write data to the specified file.
Recommended
Action
Execute the firmwareDownload command to reinstall the firmware.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.