Trce messages, Trce-1001, Trce-1002 – Dell POWEREDGE M1000E User Manual
Page 880: Trce-1003

858
Fabric OS Message Reference
53-1002749-01
TRCE-1001
5
TRCE Messages
TRCE-1001
Message
Trace dump available
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that trace dump files have been generated on the switch or the specified slot. The cause for the
dump can be one of the following:
•
PANICDUMP: Generated by panic dump.
•
WATCHDOG EXPIRED: Generated by hardware watchdog expiration.
•
MANUAL: Generated manually by issuing the
tracedump -n
command.
•
TRIGGER: Triggered by a specific Message ID generated by CRITICAL RASLog message.
Recommended
Action
Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.
TRCE-1002
Message
Trace dump
address '
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a trace dump has occurred on the switch or the specified slot, and the trace dump files
were automatically transferred from the switch to the specified FTP server.
Recommended
Action
No action is required.
TRCE-1003
Message
Trace dump
error.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that a trace dump has occurred on the switch or the specified slot, but the trace dump files were
not automatically transferred from the switch because of an FTP error such as a wrong FTP address,
FTP site is down, and network is down.