Figure 230: configure port access role menu – Allied Telesis AT-S62 User Manual
Page 663
AT-S62 Management Software Menus Interface User’s Guide
Section VI: Port Security
663
The Configure Port Access Role menu is shown in Figure 230.
Figure 230. Configure Port Access Role Menu
5. Type 1 to select Port Role.
The following prompt is displayed:
Enter new Port Role [N-None, A-Authenticator,
S-Supplicant] ->
6. If you type N for None, the port does not participate in port access
control. This is the default setting. If the port is connected to a
supplicant, type A to set the port’s role to Authenticator. If the port is
connected to an authenticator, type S to set the port’s roles to
Supplicant.
7. Repeat this procedure starting with Step 3 to configure the role of the
other ports on the switch.
After you have set port roles, go to “Configuring Authenticator Port
Parameters” on page 665 and “Configuring Supplicant Port
Parameters” on page 671 to configure the port settings.
Allied Telesyn Ethernet Switch AT-8524M - AT-S62
Marketing
User: Manager
11:20:02 02-Mar-2006
Configure Port Access Role
Configuring Port 3
1 - Port Role ......... None
R - Return to Previous Menu
Enter your selection?