AT-S62 Management Software Menus Interface User’s Guide

Section II: Advanced Operations

351

6. To change the port’s priority, type 2 to select Power Priority and, when

prompted, type C for Critical, H for High, or L for Low. A port can
belong to only one priority level at a time. The default is Low. For an
explanation of this parameter, refer to “Port Prioritization” on page 346.

7. To change the maximum amount of power the port can supply to the

device, type 3 to select Power Limit and enter a new value in milliwatts.
The default value is 15,400 mW.

A change to a parameter value is immediately activated on the switch.

8. After making your changes, type R until you return to the Main Menu.

Then type S to select Save Configuration Changes.