beautypg.com

Figure 5: system configuration menu – Allied Telesis AT-S62 User Manual

Page 53

background image

AT-S62 Management Software Menus Interface User’s Guide

Section I: Basic Operations

53

The System Configuration menu is shown in Figure 5.

Figure 5. System Configuration Menu

3. Adjust the parameters as desired.

Note

A change to any parameter in this menu, including the IP address,
subnet mask, or gateway address, is activated immediately on the
switch.

The parameters in the System Configuration menu are described
below:

1 - BOOTP/DHCP
This selection activates and deactivates the BOOTP and DHCP client
software on the switch. For information on this selection, refer to
“Activating the BOOTP or DHCP Client Software” on page 55.

2 - IP Address
This parameter specifies the IP address of the switch. You must
specify an IP address if you want the switch to function as the Master
switch of an enhanced stack or if the switch is not part of an enhanced
stack and you want to remotely manage it using a web browser, a
Telnet utility, SSH, or an SNMP management program. The IP address
must be entered in the format: xxx.xxx.xxx.xxx. The default value is
0.0.0.0. Alternatively, you can activate the BOOTP or DHCP client
software and have the switch obtain its IP configuration from a BOOTP
or DHCP server on your network. For instructions, refer to “Activating
the BOOTP or DHCP Client Software” on page 55
.

Allied Telesyn Ethernet Switch AT-8524M - AT-S62

Production Switch

User: Manager

11:20:02 02-Jan-2006

System Configuration

1 - BOOTP/DHCP .............. DISABLE
2 - IP Address .............. 0.0.0.0
3 - Subnet Mask ............. 0.0.0.0
4 - Default Gateway ......... 0.0.0.0
5 - System Name ............. Production Switch
6 - Location ................ Bldg. 12 Rm. 201
7 - Administrator ........... Jane Smith
8 - Configure System Time
9 - Fan Control Configuration

A - ARP Cache Timeout ....... 400 seconds

R - Return to Previous Menu

Enter your selection?