Section III: SNMPv3
441
Modifying a Target IP Address
To modify the target IP address in an SNMPv3 Target Address Table
entry, perform the following procedure.
1. Follow steps 1 through 3 in the procedure described in “Creating an
SNMPv3 User Table Entry” on page 386. Or, from the Main Menu type
5->5->5.
The Configure SNMPv3 Table Menu is shown in Figure 133 on page
387.
2. From the Configure SNMPv3 Table Menu, type 7 to select Configure
SNMPv3 Target Address Table.
The Configure SNMPv3 Target Address Table Menu is shown in Figure
144 on page 437.
3. From the Configure SNMPv3 Target Address Table Menu, type 3 to
select Modify SNMPv3 Table Entry.
The Modify SNMPv3 Target Address Table Menu is shown in Figure
145.
Figure 145. Modify SNMPv3 Target Address Table Menu
4. To change the Target IP Address, type 1 to select Set Target IP
Address.
Allied Telesyn Ethernet Switch AT-8524M - AT-S62
Production Switch
User: Manager
11:20:02 02-Jan-2006
Modify SNMPv3 Target Address Table
Target Addr Name ... host451
Timeout ..... 1500
Target Parameters .. SNMPmanagerPC
Retries ..... 3
IP Address ......... 198.35.11.1
UDP Port# ... 162
Storage Type ....... NonVolatile
Row Status .. Active
Tag List ........... hwengTrap hwengInform swengTrap swengInform
1 - Set Target IP Address
2 - Set Target Address UDP Port
3 - Set Target Address Timeout
4 - Set Target Address Retries
5 - Set Target Address TagList
6 - Set Target Parameters
7 - Set Storage Type
U - Update Display
R - Return to Previous Menu
Enter your selection?