Follow these steps to select your data collection hardware.

1.

Browse to the System Layout and Wiring folder on the Energy
Management Accelerator Toolkit CD image and open the Energy Data
Worksheet.

2.

Click the FactoryTalk EnergyMetrix tab then choose or enter energy device
catalog numbers.
a. Select a cell in the Cat. No. column and click the pull-down list icon.
b. Choose the appropriate Cat. No. for each data point based on the PowerMonitor and CompactLogix Device

Selection table.

To use a nonstandard energy device, select the blank at the bottom of the list and enter the catalog number.

Device

Cat. No.

Description

Communication

PowerMonitor 1000 on Ethernet

1408-EM1A-ENT

Provides kWh data, energy log, and status log only.

Ethernet

1408-EM2A-ENT

Provides kWh, kVARh, kVAHh data, demand and

projected demand values plus energy min/max, load

factor, and status log.

1408-EM3A-ENT

(2)

Provides same parameters as catalog number 1408-

EM2A-ENT plus separate voltage, current, frequency,

and power factor parameters.

PowerMonitor 3000 on Ethernet

1404-M505x-ENT

(3)

Provides full consumption and demand value

parameters, ten configurable setpoints, %THD, and

K-factor harmonic analysis.

Ethernet

1404-M605x-ENT

(2)(3)

Provides same parameters as catalog number 1404-

M505x-ENT plus waveform capture capability, and

41st order harmonic analysis.

1404-M805x-ENT

(3)

Provides same parameters as catalog number 1404-

M605x-ENT plus transient detection and capture,

and 63rd order harmonic analysis.

PowerMonitor W250

1425-D1002-MOD

PowerMonitor Wireless,100A,300V Delta

Serial or Ethernet (using

a serial to Ethernet

gateway).

1425-D1002-MOD-480

PowerMonitor Wireless,100A,480V Delta

1425-W1003-MOD

PowerMonitor Wireless,100A,300V Wye

1425-D2002-MOD

PowerMonitor Wireless,200A,300V Delta

1425-W2003-MOD

PowerMonitor Wireless, 200A,300V Wye

1425-D5002-MOD

PowerMonitor Wireless, 500A, 300V Delta

1425-D5002-MOD-480

PowerMonitor Wireless, 500A, 480V Delta

1425-W5003-MOD

PowerMonitor Wireless, 500A, 300V Wye

1425-D10002-MOD

PowerMonitor Wireless, 1000A, 300V Delta

1425-W10003-MOD

PowerMonitor Wireless, 1000A, 300V Wye

1425-D20002-MOD

PowerMonitor Wireless, 2000A, 300V Delta

1425-D20002-MOD-480 PowerMonitor Wireless, 2000A, 480V Delta
1425-W20003-MOD

PowerMonitor Wireless, 2000A, 300V Wye