Chapter 11

FactoryTalk View ME Energy Faceplates

e. Click the Communication tab.
f. Add the 193-DNENCAT port number and your E3 Plus node address to your path configuration in the

following format: Motor1, 3, #.

Import Program Control Rungs

Example logic is provided for configuring program commands. Follow these steps to import this configuration.

1. Choose a routine for importing the new rungs.

2. On a new rung, right click and select 'Import Rungs…'

3. From the ME E3 Plus Faceplate Files folder, select "E3Plus_Control_Rungs.L5X." Click Import.

4. Click Tags within the Import Content organizer.

5. Replace "_DeviceName" in the Final Name field with the name of your E3 Plus device. Click OK.

TIP

Motor_1 - the name of the EtherNet/IP Communications Auxiliary

3 - the port number of the DeviceNet Scanner of the EtherNet/IP Communications Auxiliary.

5 - the node address of the E3 Plus Overload Relay.