Show port inlinepower, Set port inlinepower, Show port inlinepower -3 set port inlinepower -3 – Enterasys Networks D-Series User Manual
Page 95
show port inlinepower
Enterasys D-Series CLI Reference
4-3
Example
This example shows how to enable inline power trap messaging on module 1:
D2(su)->set inlinepower trap enable 1
show port inlinepower
Use this command to display all ports supporting PoE.
Syntax
show port inlinepower [port-string]
Parameters
Defaults
If not specified, information for all PoE ports will be displayed.
Mode
Switch command, read‐only.
Example
This example shows how to display PoE information for port fe
.2.1
. In this case, the port’s
administrative state, PoE priority and class have not been changed from default values:
D2(su)->show port inlinepower
fe
.2.1
Port Type
Admin Oper
Priority
Class
Power(W)
---- ----
-----
----
-------- -----
--------
fe
.2.1
wireless
auto searching
low
0
15.4
set port inlinepower
Use this command to configure PoE parameters on one or more ports.
Syntax
set port inlinepower port-string {[admin {off | auto}] [priority {critical | high
| low}] [type type]}
Parameters
Defaults
None.
port‐string
(Optional) Displays information for specific PoE port(s).
port‐string
Specifies the port(s) on which to configure PoE.
admin off | auto
Sets the PoE administrative state to off (disabled) or auto (on).
priority critical |
high | low
Sets the port(s) priority for the PoE allocation algorithm to critical
(highest), high or low.
type type
Specifies a string describing the type of device connected to a port.