beautypg.com

Show port inlinepower, Set port inlinepower, Show port inlinepower -3 set port inlinepower -3 – Enterasys Networks D-Series User Manual

Page 95

background image

show port inlinepower

Enterasys D-Series CLI Reference

4-3

Example

This example shows how to enable inline power trap messaging on module 1:

D2(su)->set inlinepower trap enable 1

show port inlinepower

Use this command to display all ports supporting PoE. 

Syntax

show port inlinepower [port-string]

Parameters

Defaults

If not specified, information for all PoE ports will be displayed.

Mode

Switch command, read‐only.

Example

This example shows how to display PoE information for port fe

.2.1

. In this case, the port’s 

administrative state, PoE priority and class have not been changed from default values:

D2(su)->show port inlinepower

fe

.2.1

Port Type

Admin Oper

Priority

Class

Power(W)

---- ----

-----

----

-------- -----

--------

fe

.2.1

wireless

auto searching

low

0

15.4

set port inlinepower

Use this command to configure PoE parameters on one or more ports.

Syntax

set port inlinepower port-string {[admin {off | auto}] [priority {critical | high

| low}] [type type]}

Parameters

Defaults

None.

port‐string

(Optional) Displays information for specific PoE port(s).

port‐string

Specifies the port(s) on which to configure PoE.

admin off | auto

Sets the PoE administrative state to off (disabled) or auto (on).

priority critical | 
high | low

Sets the port(s) priority for the PoE allocation algorithm to critical 
(highest), high or low.

type type

Specifies a string describing the type of device connected to a port.