Clear dot1x auth-config, Clear dot1x auth-config -16 – Enterasys Networks D-Series User Manual
Page 478
clear dot1x auth-config
17-16
Security Configuration
Examples
This example shows how to enable reauthentication control on ports fe.1.1‐3:
D2(su)->set dot1x auth-config reauthenabled true
fe
.1.1-3
This example shows how to set the 802.1X quiet period to 120 seconds on ports fe.1.1‐3:
D2(su)->set dot1x auth-config quietperiod 120
fe
.1.1-3
clear dot1x auth-config
Use this command to reset 802.1X authentication parameters to default values on one or more
ports.
Syntax
clear dot1x auth-config [authcontrolled-portcontrol] [maxreq] [quietperiod]
[reauthenabled] [reauthperiod] [servertimeout] [supptimeout] [txperiod] [port-
string]
Parameters
Defaults
If no parameters are specified, all authentication parameters will be reset.
If port‐string is not specified, parameters will be set on all ports.
Mode
Switch command, read‐write.
Examples
This example shows how to reset the 802.1X port control mode to auto on all ports:
D2(su)->clear dot1x auth-config authcontrolled-portcontrol
This example shows how to reset reauthentication control to disabled on ports fe.1.1‐3:
D2(su)->clear dot1x auth-config reauthenabled
fe
.1.1-3
authcontrolled‐
portcontrol
(Optional) Resets the 802.1X port control mode to auto.
maxreq
(Optional) Resets the maximum requests value to 2.
quietperiod
(Optional) Resets the quiet period value to 60 seconds.
reauthenabled
(Optional) Resets the reauthentication control state to disabled (false).
reauthperiod
(Optional) Resets the reauthentication period value to 3600 seconds.
servertimeout
(Optional) Resets the server timeout value to 30 seconds.
supptimeout
(Optional) Resets the authentication supplicant timeout value to 30
seconds.
txperiod
(Optional) Resets the transmission period value to 30 seconds.
port‐string
(Optional) Resets settings on specific port(s). For a detailed description of
possible port‐string values, refer to “