beautypg.com

Set system lockout, Set system lockout -8, Show system lockout output details -8 – Enterasys Networks D-Series User Manual

Page 46

background image

set system lockout

2-8

Basic Configuration

Example

This example shows how to display user lockout settings. In this case, switch defaults have not 
been changed:

D2(su)->show system lockout

Lockout attempts: 3

Lockout time: 15 minutes.

Table 2‐3

 provides an explanation of the command output. These settings are configured with the 

set system lockout command (“

set system lockout

” on page 2‐8).

set system lockout

Use this command to set the number of failed login attempts before locking out (disabling) a read‐
write or read‐only user account, and the number of minutes to lockout the default admin super 
user account after maximum login attempts. Once a user account is locked out, it can only be re‐
enabled by a super user with the set system login command (

page 2‐4

).

Syntax

set system lockout {[attempts attempts] [time time]}

Parameters

Defaults

None.

Mode

Switch command, super user.

Example

This example shows how to set login attempts to 5 and lockout time to 30 minutes:

D2(su)->set system lockout attempts 5 time 30

Table 2-3

show system lockout Output Details

Output Field

What It Displays...

Lockout attempts

Number of failed login attempts allowed before a read-write or read-only user’s
account will be disabled.

Lockout time

Number of minutes the default admin user account will be locked out after the
maximum login attempts.

attempts attempts

Specifies the number of failed login attempts allowed before a read‐write 
or read‐only user’s account will be disabled. Valid values are 1 to 10.

time time

Specifies the number of minutes the default admin user account will be 
locked out after the maximum login attempts. Valid values are 0 to 60.