set lldp trap-interval

Enterasys D-Series CLI Reference

5-23

set lldp trap-interval

Use this command to set the minimum interval between LLDP notifications sent by this device. 
LLDP notifications are sent when a remote system change has been detected.

Syntax

set lldp trap-interval frequency

Parameters

Defaults

None.

Mode

Switch command, read‐write.

Example

This example sets the minimum interval between LLDP traps to 10 seconds.

D2(rw)->set lldp trap-interval 10

set lldp med-fast-repeat

Network connectivity devices transmit only LLDP TLVs in LLDPDUs until they detect that an 
LLDP‐MED endpoint device has connected to a port. At that point, the network connectivity 
device starts sending LLDP‐MED TLVs at a fast start rate on that port. Use this command to set the 
number of successive LLDPDUs (with LLDP‐MED TLVs) to be sent for one complete fast start 
interval.

Syntax

set lldp med-fast-repeat count

Parameters

Defaults

None.

Mode

Switch command, read‐write.

frequency

Specifies the minimum time between LLDP trap transmissions, in 
seconds. The value can range from 5 to 3600 seconds. The default 
value is 5 seconds.

count

Specifies the number of fast start LLDPDUs to be sent when an 
LLDP‐MED endpoint device is detected. Value can range from 1 to 
10. Default is 3.