Clear rmon alarm, Clear rmon alarm -12 – Enterasys Networks D-Series User Manual
Page 420
clear rmon alarm
15-12
RMON Configuration
Parameters
Defaults
None.
Mode
Switch command, read‐write.
Usage
An RMON alarm entry can be created using this command, configured using the set rmon alarm
properties command (“
” on page 15‐10), then enabled using this
command. An RMON alarm entry can be created and configured at the same time by specifying
an unused index with the set rmon alarm properties command.
Example
This example shows how to enable RMON alarm entry 3:
D2(rw)->set rmon alarm status 3 enable
clear rmon alarm
Use this command to delete an RMON alarm entry.
Syntax
clear rmon alarm index
Parameters
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to clear RMON alarm entry 1:
D2(rw)->clear rmon alarm 1
index
Specifies an index number for this entry. Maximum number or entries is
50. Maximum value is 65535.
enable
Enables this alarm entry.
index
Specifies the index number of entry to be cleared.