set snmp notifyfilter
7-34
SNMP Configuration
set snmp notifyfilter
Use this command to create an SNMP notify filter configuration. This identifies which
management targets should NOT receive notification messages, which is useful for fine‐tuning the
amount of SNMP traffic generated.
Syntax
set snmp notifyfilter profile subtree oid-or-mibobject [mask mask] [included |
excluded] [volatile | nonvolatile]
Parameters
Defaults
If not specified, mask is not set.
If not specified, subtree will be included.
If storage type is not specified, nonvolatile (permanent) will be applied.
Mode
Switch command, read‐write.
Usage
See “
” on page 7‐28 for more information about notify filters.
Example
This example shows how to create an SNMP notify filter called “pilot1” with a MIB subtree ID of
1.3.6:
D2(su)->set snmp notifyfilter pilot1 subtree 1.3.6
clear snmp notifyfilter
Use this command to delete an SNMP notify filter configuration.
Syntax
clear snmp notifyfilter profile subtree oid-or-mibobject
profile
Specifies an SNMP filter notify name.
subtree oid‐or‐
mibobject
Specifies a MIB subtree ID target for the filter.
mask mask
(Optional) Applies a subtree mask.
included |
excluded
(Optional) Specifies that subtree is included or excluded.
volatile |
nonvolatile
(Optional) Specifies a storage type.