set logging application

Enterasys D-Series CLI Reference

14-7

Mode

Switch command, read‐only.

Example

This example shows how to display system logging information pertaining to the SNMP 
application.

D2(ro)->show logging application SNMP

Application Current Severity Level

---------------------------------------------

90 SNMP 6

1(emergencies) 2(alerts) 3(critical)

4(errors) 5(warnings) 6(notifications)

7(information) 8(debugging)

Table 14‐33

 provides an explanation of the command output.

set logging application

Use this command to set the severity level of log messages for one or all applications.

Syntax

set logging application {[mnemonic | all]} [level level]

Parameters

Table 14-33

show logging application Output Details

Output Field

What it displays...

Application

A mnemonic abbreviation of the textual description for
applications being logged.

Current Severity Level

Severity level at which the server is logging messages for the
listed application. This range (from 1 to 8) and its associated
severity list is shown in the CLI output. For a description of these
entries, which are set using the set logging application
command, refer to “

set logging application

” on page 14-7.

mnemonic

pecifies a case sensitive mnemonic abbreviation of an application to be 
logged. This parameter will vary depending on the number and types of 
applications running on your system. To display a complete list, use the 
show logging application command as described in 

show logging 

application

” on page 14‐6. Sample mnemonics and their corresponding 

applications are listed in 

Table 14‐34 

on page 14‐8.

Note: Mnemonic values are case sensitive and must be typed as they appear in

Table 14-34.

all

Sets the logging severity level for all applications.