beautypg.com

Configuring spanning tree bridge parameters, Purpose, Configuring spanning tree bridge parameters -3 – Enterasys Networks D-Series User Manual

Page 221: Purpose -3

background image

Configuring Spanning Tree Bridge Parameters

Enterasys D-Series CLI Reference

8-3

learning and the priority vector is worse than that already held by the port. If a disputed BPDU is 
received, the port is forced to the listening state. When an inferior designated BPDU with the 
learning bit set is received on a designated port, its state is set to discarding to prevent loop 
formation. Note that the Dispute mechanism is always active regardless of the configuration 
setting of Loop Protection.

Loop Protect operates as a per port, per MST instance feature. It should be set on inter‐switch 
links. It is comprised of several related functions:

Control of port forwarding state based on reception of agreement BPDUs

Control of port forwarding state based on reception of disputed BPDUs

Communicating port non‐forwarding status through traps and syslog messages

Disabling a port based on frequency of failure events

Port forwarding state in the designated port is gated by a timer that is set upon BPDU reception. It 
is analogous to the rcvdInfoWhile timer the port uses when receiving root information in the root/
alternate/backup role. 

There are two operational modes for Loop Protect on a port. If the port is connected to a device 
known to implement Loop Protect, it uses full functional mode. Otherwise the port operates in 
limited functional mode. 

Connection to a Loop Protect switch guarantees that the alternate agreement mechanism is 
implemented. This means the designated port can rely on receiving a response to its proposal 
regardless of the role of the connected port, which has two important implications. First, the 
designated port connected to a non‐root port may transition to forwarding. Second, there is no 
ambiguity when a timeout happens; a Loop Protect event has occurred. 

In full functional mode, when a type 2 BPDU is received and the port is designated and point‐to‐
point, the timer is set to 3 times helloTime. In limited functional mode there is the additional 
requirement that the flags field indicate a root role. If the port is a boundary port the MSTIs for 
that port follow the CIST, that is, the MSTI port timers are set according to the CIST port timer. If 
the port is internal to the region then the MSTI port timers are set independently using the 
particular MSTI message.

Message age expiration and the expiration of the Loop Protect timer are both Loop Protect events. 
A notice level syslog message is produced for each such event. Traps may be configured to report 
these events as well. A syslog message and trap may be configured for disputed BPDUs.

It is also configurable to force the locking of a SID/port for the occurrence of one or more events. 
When the configured number of events happen within a given window of time, the port is forced 
into blocking and held there until it is manually unlocked via management.

Configuring Spanning Tree Bridge Parameters

Purpose

To display and set Spanning Tree bridge parameters, including device priorities, hello time, 
maximum wait time, forward delay, path cost, and topology change trap suppression.