Enterasys Networks D-Series User Manual
Page 297
set garp timer
Enterasys D-Series CLI Reference
9-25
Defaults
None.
Mode
Switch command, read‐write.
Usage
The setting of these timers is critical and should only be changed by personnel familiar with the
802.1Q standards documentation, which is not supplied with this device.
Examples
This example shows how to set the GARP join timer value to 100 centiseconds for all ports:
D2(su)->set garp timer join 100 *.*.*
This example shows how to set the leave timer value to 300 centiseconds for all ports:
D2(su)->set garp timer leave 300 *.*.*
This example shows how to set the leaveall timer value to 20000 centiseconds for all ports:
D2(su)->set garp timer leaveall 20000 *.*.*
leaveall timer‐
value
Sets the GARP leaveall timer in centiseconds (Refer to 802.1Q standard.)
port‐string
Specifies the port(s) on which to configure GARP timer settings. For a
detailed description of possible port‐string values, refer to “