Set summertime, Set summertime date, Set summertime -18 set summertime date -18 – Enterasys Networks D-Series User Manual
Page 56
set summertime
2-18
Basic Configuration
Mode
Switch command, read‐only.
Example
This example shows how to display daylight savings time settings:
D2(su)->show summertime
Summertime is disabled and set to ''
Start : SUN APR 04 02:00:00 2004
End : SUN OCT 31 02:00:00 2004
Offset: 60 minutes (1 hours 0 minutes)
Recurring: yes, starting at 2:00 of the first Sunday of April and ending at 2:00
of the last Sunday of October
set summertime
Use this command to enable or disable the daylight savings time function.
Syntax
set summertime {enable | disable} [zone]
Parameters
Defaults
If a zone name is not specified, none will be applied.
Mode
Switch command, read‐only.
Example
This example shows how to enable daylight savings time function:
D2(su)->set summertime enable
set summertime date
Use this command to configure specific dates to start and stop daylight savings time. These
settings will be non‐recurring and will have to be reset annually.
Syntax
set summertime date start_month start_date start_year start_hr_min end_month
end_date end_year end_hr_min [offset_minutes]
Parameters
enable | disable
Enables or disables the daylight savings time function.
zone
(Optional) Applies a name to the daylight savings time settings.
start_month
Specifies the month of the year to start daylight savings time.
start_date
Specifies the day of the month to start daylight savings time.